Fault Protection: Protected against reverse and overvoltage events from –24 V to +24
Channels: Eight 5-volt logic level GPIO configurable channels in groups of two as inputs or outputs
GPIO Input Logic Levels: High 2.0 V min, Low 0.8 V max
Galvanic Isolation: 500 Vpeak
GPIO State Indicators: Eight bicolor (red = high, green = low) LEDs with adjustable pulse width modulation (PWM) illumination control
Control: GPIO 8-bit read or write (groups of two)
Field Connector: Phoenix Contact 10-circuit
Power: +5 VDC @ 51 mA
Maximum Installed Modules: 10