Solar Panel & Battery Combined Power Output: Drives the FX-2100 UMC DC-to-DC power converter
Maximum Recommended Panel Power: 65 W
Solar Panel Fuse: Ceramic cartridge, user replaceable
Rated Battery Output Current: 5 A
Nominal Battery Voltage: 12 V
Battery Fuse: Ceramic cartridge, user replaceable
Maximum Voc1: 27 V
Recommended Max Voc1 at STC2: 22 V
Minimum Battery Voltage for Normal Operation: 7.2 V
Dead Battery Recovery: Trickle charge
Maximum Input Short Circuit Current: 5 A
Continuous Rated Load Current: 5 A
Maximum Input Current: 9 A
Charge Profile: Multi-stage with temperature compensation
Absorption Voltage: 14.2 V
Absorption Time: 2 hours
Float Voltage: 13.8 V
Load Disconnect/Reconnect Voltage: 11.4 V/12.5 V
Battery Temperature Compensation: -28mV/˚C
Electrical Efficiency: 96% to 98%
Tracking Efficiency: 99% typical
MPPT Tracking Speed: 15 Hz
Operating Power Consumption: 150 µA
Night Power Consumption: 125 µA
LED Status Indicators: GV-5: bi-color, Battery: green, Solar panel: green
Alternate Battery Chemistry GV-5 Series Charge Controller Plug-In Options: Lithium Iron Phosphate (4S) 13.2 V (2000-218016), Lithium Cobalt/Polymer (3S) 11.1 V (2000-218024) & Lithium Cobalt/Polymer (4S) 14.8 V (2000-218032)
SUPPLIED CONNECTORS
Battery Connector: Plug, Female, 2-position, 3.81 mm pitch, (1010-076523)
Solar Panel Connector: Plug, Female, 3-position, 3.81 mm pitch, (1010-076621)
- Voc: Voltage open circuit
- Standard Test Conditions (STC) is the set of criteria that a solar panel is tested at. Since voltage and current change based on temperature and intensity of light, among other criteria, all solar panels are tested to the same standard test conditions. This includes cell temperature (25˚C), light intensity (1 kW/meter² noon-time sun), and atmospheric density (1.5), or the sun’s angle directly-perpendicular to the solar panel at 500 feet above sea level.