Fault Protection: Output short-to-ground, output short to V+, over current, over temperature & reverse polarity
Output Stage: DMOS H-bridge
Load Current: 2 A continuous (convective), >2 A to ≤ 4 A continuous (forced air), 5 A peak (<100 ms T= 1s), simultaneous operation of both drivers
Maximum Voltage: 35 V
Galvanic Isolation: 500 VDC
Maximum Voltage for Short Circuit Protection: 32 V
Source On Resistance: 220 mΩ typical @ 3 A
Sink On Resistance: 230 mΩ typical @ 3 A
Initial Peak Short Circuit Current Limit: 100 A
Source Current Shutdown: 8 A typical
Sink Current Shutdown: 8 A typical
Shutdown Delay Time: 50 µs
Thermal Overload Trip Temperature: 175˚C typical
Fan Enable: Any motor active
GPIO & Fault state indicators: Four bicolor (red = high, green = low) GPIO LEDs and two fault state LEDs with adjustable pulse width modulation (PWM) illumination control
Control: GPIO 4-bit motor CW & CCW
Field Connector: Phoenix Contact 10-circuit
Power: +5 VDC @ 7 mA
Maximum Installed Modules: 10