FX-2210 Low-Side Switch Module

Four galvanically isolated Infineon BTS 141TC switch-to-ground (sink) power FET switches.

Please Contact Us for a Price and Delivery Quotation 

SKU: 2000-221009 Category:

Fault Protection: Over current, over temperature, load dump, and reverse battery polarity 1

Load Current: 3 A continuous (convective), >3 A to ≤5 A  continuous (forced air), >5 A to ≤8 A 50% duty cycle (forced air), unrestricted switch-on combinations

Maximum Voltage for Short Circuit Protection: 32 V

Load Dump: 84 V

Galvanic Isolation: 500 VDC

RDS (on): 31 mΩ typical

Initial Peak Short Circuit Current Limit: 100 A

Current Limit: 35 A typical within 350 µs

Thermal Overload Trip Temperature: 165˚C typical

Fan Enable: Any switch on

GPIO State Indicators: Four bicolor (red = high, green = low) LEDs with adjustable pulse width modulation (PWM) illumination control

Control: GPIO 4-bit on/off

Field Connector: Phoenix Contact 10-circuit

Power: +5 VDC @ 7 mA

Maximum Installed Modules: 10

  1. Reverse current is limited by the load and-or power supply current limit. Reverse current protection is NOT provided to the field equipment. The reverse current path is thru the FX-2000 module power FET body diode and duration is limited by the respective module heatsink capacity. FX-2230 thermal protection is not active in the reverse current mode.

 

Dimensions 2.5 × 2.5 × 1 in